By Ernest V. Garcia Ph.D., James R. Galt Ph.D. (auth.), Vasken Dilsizian, Jagat Narula (eds.)

ISBN-10: 1461455499

ISBN-13: 9781461455493

ISBN-10: 1461455510

ISBN-13: 9781461455516

The goal of the 4th version of the Atlas of Nuclear Cardiology is to supply physicians and scholars in cardiology, radiology, and nuclear drugs who wish the newest details within the box of cardiovascular nuclear drugs updated and finished details on advances in instrumentation, radiotracers, protocols, and scientific stories. in contrast to different books which are slender of their scope of both know-how and strategy or medical reports, the 4th version of the Atlas will current diagnostic algorithms and schematic diagrams built-in with nuclear cardiology techniques generously interspersed with colour illustrations to stress key options in cardiovascular body structure, pathology, and metabolism suitable for the scientific perform of cardiology. The atlas emphasizes today’s most modern details, assembly the necessities when you can be utilizing the ebook as a reference resource for certifying or re-certifying in cardiology, nuclear cardiology, nuclear drugs or radiology.

Hybrid PET/CT and SPECT/CT characterize new applied sciences that have been brought lately in scientific medication and are evolving speedily with a number of advancements in instrumentation, imaging tactics in addition to in scientific trials that help the elevated position of those applied sciences in medical perform. As such, an up to date 4th version of the Atlas is necessary to ensure that the clinicians stay present with the imaging box and preserve their talents. Imaging protocols with those applied sciences need to be up to date and/or elevated with a purpose to gather prime quality photos at a discounted radiation burden to the sufferer whereas advancing the appliance of those concepts for extra complicated sickness detection. for that reason, past considerably updating the chapters from the third version, 2 new chapters might be brought within the 4th variation, which displays the improved medical purposes of the applied sciences long ago three years. the recent chapters are as follows: "Hybrid SPECT/CT and PET/CT Imaging" and a devoted bankruptcy on "Radiation security and publicity: medical Decision-Making and the Risk-Benefit Ratio". bankruptcy 7 from the third variation may be deleted.

The up-to-date Atlas will function a reference resource for all cardiologists, radiologists, and nuclear drugs physicians drawn to the main up to date methods to noninvasive diagnostic cardiovascular nuclear imaging strategies for the review of sufferers with identified or suspected coronary artery ailment in addition to non-coronary center sickness. it is going to additionally function a prepared reference textbook for clinical scholars and citizens drawn to the perform of cardiovascular medicine.

Show description

Read or Download Atlas of Nuclear Cardiology PDF

Similar nuclear books

Download e-book for kindle: The Russian Nuclear Shield from Stalin to Yeltsin (St. by J. Mathers

This paintings makes broad use of Soviet assets to supply a whole research of Moscow's ballistic missile defence coverage, from its origins to post-Soviet advancements. It considers the Soviets' motivations for pursuing an anti-ballistic missile potential and the level in their luck, and divulges that ballistic missile defence coverage was once utilized by each political management from Krushchev to Yeltsin as a way of sending indications approximately Moscow's intentions to the West.

Get Infrastructure and methodologies for the justification of PDF

The capability improvement of any nuclear strength programme calls for a rigorous justification technique equipped upon an target infrastructure, reviewing the big regulatory, fiscal and technical info required to correctly pick out implementation of this type of long term dedication. either new entrants and people nations wishing to renovate their nuclear fleets after a moratorium might want to improve and follow applicable infrastructures to study the justification of the capability use of nuclear strength.

Claus Grupen, Mark Rodgers's Radioactivity and Radiation: What They Are, What They Do, PDF

This booklet lays the principles so you might comprehend all that you simply continually desired to find out about radioactivity. It starts off by way of starting up crucial information regarding the constitution of topic, how radiation happens and the way it may be measured. It is going directly to discover the gigantic merits of radioactivity via its many purposes, and in addition the potential dangers linked to its use.

Extra resources for Atlas of Nuclear Cardiology

Example text

B) Direct conversion: this figure illustrates how a cadmium zinc telluride (CZT) detector works where the detector absorbs the gamma ray from the patient, directly converting its energy to charge carriers that form an electrical pulse with the information of the energy of the event and with the location being given by the location of the pixel within the CZT detector where the event took place. This more direct transfer of energy and location information results in superior energy and spatial resolution over conventional SPECT cameras.

The figure shows short, vertical, and horizontal oblique axis slices starting b After AC with stress images in the first row and immediately below the corresponding resting images. The top right black/white images show planar reprojections. Note the fixed defect in the inferobasal wall. (b) 530c system images with AC are shown. This the same patient as in (a) but who is now using a CT transmission for AC shown in the top right black/white panels. Note the increased tracer uniformity throughout the left ventricle and a normally perfused inferior wall.

Physical factors that may affect single-photon emission CT (SPECT) image formation. Accurate reconstructions of the radionuclide distribution in the body depend on accurate detection of the emitted g-rays. However, not all of the g-rays emitted by a radionuclide emerge from the body, and those that do are not all detected in the right place. These complicating factors degrade the resulting image. The three factors that cause degradations in SPECT are attenuation, scatter, and distance-dependent resolution or blur of collimation.

Download PDF sample

Atlas of Nuclear Cardiology by Ernest V. Garcia Ph.D., James R. Galt Ph.D. (auth.), Vasken Dilsizian, Jagat Narula (eds.)


by Robert
4.4

Rated 4.37 of 5 – based on 19 votes